Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment

https://aino.repo.nii.ac.jp/records/782
https://aino.repo.nii.ac.jp/records/782
9d74dfac-e8db-4dea-8a08-5be667ba9d7a
名前 / ファイル ライセンス アクション
Measurement Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment (152.1 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2022-07-13
タイトル
タイトル Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment
言語 en
言語
言語 eng
キーワード
主題 Coughing, Expiratory muscle thickness, Ultrasonic diagnostic equipment
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 Yamashina, Yoshihiro

× Yamashina, Yoshihiro

en Yamashina, Yoshihiro

ja ISNI

Search repository
Tabira, Kazuyuki

× Tabira, Kazuyuki

en Tabira, Kazuyuki

ja ISNI

Search repository
Miyamoto, Koji

× Miyamoto, Koji

en Miyamoto, Koji

ja ISNI

Search repository
Aoyama, Hiroki

× Aoyama, Hiroki

en Aoyama, Hiroki

ja ISNI

Search repository
Yamato, Yousuke

× Yamato, Yousuke

en Yamato, Yousuke

ja ISNI

Search repository
Hori, Hirofumi

× Hori, Hirofumi

en Hori, Hirofumi

ja ISNI

Search repository
Morita, Emiko

× Morita, Emiko

en Morita, Emiko

ja ISNI

Search repository
Sakagami, Nami

× Sakagami, Nami

en Sakagami, Nami

ja ISNI

Search repository
Hirayama, Tomoko

× Hirayama, Tomoko

en Hirayama, Tomoko

ja ISNI

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background : Coughing is one of the bodyʼs defense mechanisms, where the sputum expectoration function plays an important role. Expiratory muscle activity is required to increase the expiratory flow velocity between the third and fourth phases of a cough.
However, few studies have reported the dynamics of abdominal muscle groups during coughing, such as those of the transverse abdominal muscle using ultrasonic image diagnostic equipment. Therefore, this study was aimed to examine the thickness of the
external oblique, internal oblique, and transverse abdominal muscles during coughing.
Methods : Nine normal healthy males were included in this study. The measurement posture was the supine position. Ultrasound images of the external oblique, internal oblique, and transverse abdominal muscles were recorded during expiration at rest and
coughing, in three rounds of 10 seconds each. The image analysis used OsiriX to view static images of the muscle thickness at maximum muscle hypertrophy during expiration at rest and on coughing, measured in units of 1 mm. The average thickness was calculated using the measurements obtained from three rounds.
Results : The thickness of the internal oblique and transverse abdominal muscles increased significantly during coughing compared with expiration at rest. However, there was no significant difference in the thickness of the external oblique muscle during coughing and expiration at rest.
Conclusion : The thickness of the internal oblique and transverse abdominal muscles increased significantly during coughing compared with expiration at rest, but there was no significant difference in the thickness of the external oblique muscle between these two phases.
言語 en
内容記述
内容記述タイプ Other
内容記述 健常男性9名(平均23.2歳)を対象に、背臥位で安静呼気時および咳嗽時の外腹斜筋、内腹斜筋および腹横筋の超音波画像10秒間を3回記録した。OsiriXを用いた画像解析により安静呼気時および咳嗽時の最大筋肥厚時の静止画像を抽出し筋厚を1mm単位で測定した。3回の筋厚計測から平均値を求めた。その結果、安静呼気時と比べて咳嗽時の内腹斜筋および腹横筋の筋厚は有意に増大し、外腹斜筋の筋厚には有意な変化がみられなかった。以上より、咳嗽時には深部の筋活動が大きいと考えられた。
言語 ja
書誌情報 en : AINO JOURNAL

巻 16, 号 1, p. 31-34, ページ数 4, 発行日 2018-03-31
出版者
出版者 AINO UNIVERSITY
言語 en
ISSN
収録物識別子タイプ PISSN
収録物識別子 1348-480X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:21:03.811610
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3