{"created":"2023-05-15T12:17:05.695941+00:00","id":782,"links":{},"metadata":{"_buckets":{"deposit":"5ae9a6de-6165-4ab3-81e9-636c75931e35"},"_deposit":{"created_by":8,"id":"782","owners":[8],"pid":{"revision_id":0,"type":"depid","value":"782"},"status":"published"},"_oai":{"id":"oai:aino.repo.nii.ac.jp:00000782","sets":["7:74"]},"author_link":["2755","2749","2750","2756","2753","2751","2754","2748","2752"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-03-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"34","bibliographicPageStart":"31","bibliographicVolumeNumber":"16","bibliographic_titles":[{},{"bibliographic_title":"AINO JOURNAL","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"健常男性9名(平均23.2歳)を対象に、背臥位で安静呼気時および咳嗽時の外腹斜筋、内腹斜筋および腹横筋の超音波画像10秒間を3回記録した。OsiriXを用いた画像解析により安静呼気時および咳嗽時の最大筋肥厚時の静止画像を抽出し筋厚を1mm単位で測定した。3回の筋厚計測から平均値を求めた。その結果、安静呼気時と比べて咳嗽時の内腹斜筋および腹横筋の筋厚は有意に増大し、外腹斜筋の筋厚には有意な変化がみられなかった。以上より、咳嗽時には深部の筋活動が大きいと考えられた。","subitem_description_type":"Abstract"}]},"item_10002_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"健常男性9名(平均23.2歳)を対象に、背臥位で安静呼気時および咳嗽時の外腹斜筋、内腹斜筋および腹横筋の超音波画像10秒間を3回記録した。OsiriXを用いた画像解析により安静呼気時および咳嗽時の最大筋肥厚時の静止画像を抽出し筋厚を1mm単位で測定した。3回の筋厚計測から平均値を求めた。その結果、安静呼気時と比べて咳嗽時の内腹斜筋および腹横筋の筋厚は有意に増大し、外腹斜筋の筋厚には有意な変化がみられなかった。以上より、咳嗽時には深部の筋活動が大きいと考えられた。","subitem_description_type":"Other"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1348-480X","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yoshihiro, Yamashina","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2748","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kazuyuki, Tabira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2749","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koji, Miyamoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2750","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroki, Aoyama","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2751","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yosuke, Yamato","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2752","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirofumi, Hori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2753","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Emiko, Morita","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2754","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nami, Sakagami","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2755","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tomoko, Hirayama","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2756","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-27"}],"displaytype":"detail","filename":"Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment.pdf","filesize":[{"value":"152.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment","url":"https://aino.repo.nii.ac.jp/record/782/files/Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment.pdf"},"version_id":"c4b76914-d14d-41dc-9369-42cd28981cde"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"*咳嗽","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"*超音波診断","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"*腹壁筋(超音波診断)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"*腹斜筋(超音波診断)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"*腹横筋(超音波診断)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"成人(19〜44)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"男","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment"},{"subitem_title":"超音波診断装置を用いた咳嗽時の呼気筋厚測定(Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment)","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"8","path":["74"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-07-13"},"publish_date":"2022-07-13","publish_status":"0","recid":"782","relation_version_is_last":true,"title":["Measurement of expiratory muscle thickness during coughing using ultrasonic diagnostic equipment"],"weko_creator_id":"8","weko_shared_id":8},"updated":"2023-05-15T12:25:15.670986+00:00"}