WEKO3
アイテム
The problem of using deltoid muscle for intramuscular injection
https://aino.repo.nii.ac.jp/records/332
https://aino.repo.nii.ac.jp/records/33266b1a84f-8898-49b8-b103-02864423f843
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | [ELS]紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-27 | |||||
タイトル | ||||||
タイトル | The problem of using deltoid muscle for intramuscular injection | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | deltoid muscle | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | intramuscular injection | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | axillary nerve | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | human cadaver | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | acromion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11877461 | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P | |||||
論文名よみ | ||||||
タイトル | The problem of using deltoid muscle for intramuscular injection | |||||
著者 |
FUJIMOTO, Etsuko
× FUJIMOTO, Etsuko |
|||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Basic Nursing, Ishikawa Prefectural Nursing University | |||||
記事種別(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Original article | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Although the deltoid muscle has often been used as a site of intramuscular injection (ImI), the risk of axillary nerve injury caused by the needle is overlooked. The present study examined the potential risk of needle insertion in the deltoid muscle during the dissection of 14 shoulders from cadavers. A needle was pierced into the deltoid muscle from the overlying skin at the middle of the horizontal line, as described in the standard nursing textbooks. The axillary nerve is located beneath the deltoid muscle, with its branches extending through the quadrangular space as far as the anterior part of the deltoid muscle. It was found that the needle passed very close to the axillary nerve trunk in all cases. This finding suggests that the deltoid muscle is not appropriate for ImI, even if the anterior part is selected as the injection site. This study warns nurse practitioners know of the potential nerve injury as the result of ImI in the deltoid muscle. | |||||
書誌情報 |
en : Aino journal 巻 6, 発行日 2008-03-31 |
|||||
表示順 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 9 | |||||
アクセション番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | KJ00005223108 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1348480X |