| Item type |
[ELS]紀要論文 / Departmental Bulletin Paper(1) |
| 公開日 |
2019-03-27 |
| タイトル |
|
|
タイトル |
Diaphragm perforation, a rare complication of V-P shunt surgery |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| キーワード |
|
|
主題 |
normal pressure hydrocephalus, V-P shunt, perforation, diaphragm |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
| 著者 |
Takagaki, Masao
Hamahata, Tetsuzou
Saeki, Akio
|
| 抄録(英) |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Ventriculoperitoneal shunt surgery is the most widely used procedure in the treatment of hydrocephalus. However, this invasive procedure has been associated with several delayed complications. A 64-year-old male had unusual pneumonia caused by diaphragm perforation due to a ventriculoperitoneal (V-P) shunt catheter 3 years after V-P shunting for secondary normal pressure hydrocephalus after thalamic hemorrhage. Aspiration of hydrothorax of cerebrospinal fluid and removal of the catheter is the only treatment option for patients to alleviate such a lethal pneumonia. Probable causes of this rare complication are discussed, and attention is drawn to the possibility of its appearance and early recognition of respiratory distress. |
|
言語 |
en |
| 書誌情報 |
en : AINO JOURNAL
巻 5,
号 1,
p. 77-80,
ページ数 4,
発行日 2006
|
| ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1348480X |