Reliability of Cardiotocography in the Assessment of Fetal Heart Rate Patterns

https://aino.repo.nii.ac.jp/records/2000280
https://aino.repo.nii.ac.jp/records/2000280
4528b3c7-005f-4bb6-ac93-a04be0697fda
名前 / ファイル ライセンス アクション
Hitomi Hitomi KIKUCHI et al. Reliability of Cardiotocography in the Assessment of Fetal Heart Rate Patterns.pdf (67 KB)
アイテムタイプ 紀要論文 / Departmental Bulletin Paper(1)
公開日 2026-05-20
タイトル
タイトル Reliability of Cardiotocography in the Assessment of Fetal Heart Rate Patterns
言語 en
言語
言語 eng
キーワード
主題 FHR pattern classification, TRIUM, kappa score, inter-rater reliability, intra-rater reliability
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 Kikuchi, Hitomi

× Kikuchi, Hitomi

en Kikuchi, Hitomi

Search repository
Ikeda, Tomoaki

× Ikeda, Tomoaki

en Ikeda, Tomoaki

Search repository
Murabayashi, Nao

× Murabayashi, Nao

en Murabayashi, Nao

Search repository
抄録
内容記述タイプ Abstract
内容記述 The classification of fetal heart rate (FHR) patterns is performed visually by obstetricians and gynecol-ogists, which sometimes results in problematic discrepancies between assessments. Cardiotocography (CTG), which automatically performs pattern classifications using a computer, has been introduced recently to address this problem. The purpose of this study was to examine the reliability of assess-ments by obstetricians and by CTG (Trium), as well as identify factors that contribute to differences in assessments. Methods: Obstetricians used the FHR guidelines to perform pattern classifications ac-cording to baseline, variability, and deceleration of the FHR. Inter-rater reliability, Trium-reliability, and intra-rater reliability were evaluated using Kappa scores. Results: There was a high degree of agreement among obstetricians involved in the assessment of FHR patterns. However, deceleration of the FHR was associated with disagreement with the Trium CTG automatic assessment system, and there were clear differences in assessments between mild variable and mild late, as well as severe var-iable and severe late patterns. Conclusions: These findings suggest that the deceleration category pro-gram of Trium CTG could be improved to obtain results closer to those of visual assessments.
言語 en
書誌情報 en : AINO JOURNAL

巻 23, 号 1, p. 1-5, 発行日 2026-04-30
出版者
ISSN
収録物識別子タイプ PISSN
収録物識別子 1348-480X
戻る
0
views
See details
Views

Versions

Ver.1 2026-05-20 08:21:31.765100
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3