{"created":"2023-05-15T12:17:06.616461+00:00","id":797,"links":{},"metadata":{"_buckets":{"deposit":"6d7b6ab0-7cfd-49aa-937d-3b33ee11ac2d"},"_deposit":{"created_by":8,"id":"797","owners":[8],"pid":{"revision_id":0,"type":"depid","value":"797"},"status":"published"},"_oai":{"id":"oai:aino.repo.nii.ac.jp:00000797","sets":["7:76"]},"author_link":["2948","2823","2828","2943","2824","2942","2820","2826","2827","2945","2944","2821","2946","2822","2947","2949","2825","2941"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"19","bibliographicPageStart":"13","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"AINO JOURNAL"},{"bibliographic_title":"AINO JOURNAL","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The author conducted experimental studies of active flexion/passive extension of the IP・MP joints of thumbs fitted with a Dynamic Extension Splint by using and not using rubber band traction apparatus, and evaluated the electromyographical wave pattern and electromyographic muscle activities of the EPL and FPL of eight healthy male adults. Statistically significant differences were not detected between the experimental (passive extension using rubber band traction apparatus) and control (active extension) groups. The authors concluded that there is a limitation of the effectiveness of active flexion/passive extension of the IP・MP thumb joints conducted with a rubber band traction apparatus as a postoperative early motion therapy for EPL tendon rupture.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"関節装具装着時のIP/MP関節の長母指伸筋運動パターンについて検討した。男性健常者8名(平均21.75±0.43歳)を対象とした。伸展ダイナミックスプリントを装着した親指のIP/MP関節の屈曲/伸展運動を、筋電図を用いて評価した。ゴムバンド牽引装具を装着した場合の母指のIP/MP関節の伸展を他動伸展とした。長母指伸筋活動の強度を、自動屈曲/他動伸展(実験群)と、自動屈曲/自動伸展(対照群)とで比較した。長母指伸筋活動の基準値として、長母指屈筋活動も測定した。実験群の他動伸展と対照群の自動伸展に統計学的有意差は認められなかった。本研究結果から、長母指伸腱断裂の術後早期運動療法として用いるゴムバンド牽引装具の有効性には限界があると考えられた。","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AINO UNIVERSITY"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11877461","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1348-480X","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"MIYAMOTO, Chimi"}],"nameIdentifiers":[{"nameIdentifier":"2941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MIYAMOTO, Akira"}],"nameIdentifiers":[{"nameIdentifier":"2942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KANEKIYO, Kenji"}],"nameIdentifiers":[{"nameIdentifier":"2943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"NAKANO, Norihiko"}],"nameIdentifiers":[{"nameIdentifier":"2944","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ZANG, Chi"}],"nameIdentifiers":[{"nameIdentifier":"2945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TAKAHATA, Shuhei"}],"nameIdentifiers":[{"nameIdentifier":"2946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"YAMANE, Shingo"}],"nameIdentifiers":[{"nameIdentifier":"2947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SAKAI, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"2948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"IDE, Chizuka"}],"nameIdentifiers":[{"nameIdentifier":"2949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chimi, Miyamoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akira, Miyamoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kenji, Kanekiyo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Norihiko, Nakano","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chi, Zhang","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shuhei, Takahata","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2825","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shingo, Yamane","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroshi, Sakai","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chizuka, Ide","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2828","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-27"}],"displaytype":"detail","filename":"Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus.pdf","filesize":[{"value":"612.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus","url":"https://aino.repo.nii.ac.jp/record/797/files/Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus.pdf"},"version_id":"905c009f-a73f-49bc-94ba-82651c56e28c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Electromyography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Extensor Pollicis Longus (EPL)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"healthy adults","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"fine wire electrode","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus"},{"subitem_title":"Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"8","path":["76"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-11-21"},"publish_date":"2022-11-21","publish_status":"0","recid":"797","relation_version_is_last":true,"title":["Electromyography-based evaluation of extensor pollicis longus muscle activities in healthy volunteers fitted with a rubber band traction apparatus"],"weko_creator_id":"8","weko_shared_id":8},"updated":"2023-05-15T12:23:53.496304+00:00"}